Search results for "electromagnetic [current]"
showing 10 items of 1008 documents
Single-Center Retrospective Series of Intracranial Aneurysms Treated with the Barricade Coil System: Immediate and Six-Month Results
2020
Abstract Intracranial aneurysms (IAs) are most commonly found at the branch points of large arteries that form the circle of Willis. The prevalence of IAs in the adult population is 1–5%. IAs rupture is associated with subarachnoid haemorrhage (SAH) in 6–8 cases per 100 000 population, causing mortality in 40–50%. Aneurysm treatment is used to prevent rupture or rebleeding (for ruptured IAs). Randomised trials demonstrated the superiority of endovascular treatment (EVT) of ruptured aneurysms with coil systems over surgery. The objective of the study was to evaluate the effectiveness of the Barricade coil system in the treatment of intracranial aneurysms. Detachable platinum coils, since the…
Design and Assessment of Optimized EMI Filters for Avionic Applications
2018
This paper presents a procedure to design EMI filters to reduce the electromagnetic disturbances generated by electrical apparatus used in avionic environment. The method proposed can be useful to save weight and size of the attenuation systems, and keep their effectiveness in agreement with the standard requirements. A design of a set of different filters with different topological characteristics is presented for a case study about an electrical actuator used for an aircraft onboard application. Performances and reliabilities of the attenuation systems are assessed by suitable full compliance experimental tests.
Agar-based phantoms for skin diagnostic imaging
2020
Agar-based skin phantoms with different thicknesses and hemoglobin concentration were evaluated for diagnostics of skin lesions by RGB imaging. Scattering properties of the phantoms were simulated using intralipid, absorption properties – using lyophilized powder of human hemoglobin. RGB images of phantoms were captured by self-developed laboratory made devices. The algorithm for calculation of chromophore concentrations are based on Beer-Lambert law and includes the photon path length evaluated from the measured photon-time-of-flight signals. Optical properties and chromophore concentration maps of phantoms obtained from RGB images were analyzed. The influence of chromophore concentration …
Observation of the rare B(s)(0) + decay from the combined analysis of CMS and LHCb data.
2015
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported licence.-- et al.
En-Face differential absorption optical coherence tomography with gold nanorods as the contrast agent
2008
A new variety of nanoparticles showing unique and characteristic optical properties, appeals for its use as contrast agents in medical imaging. Gold nanospheres, nanorods and nanoshells with a silica core are new forms of promising contrast agents which can be tuned to specific absorption or scattering characteristics within the near-infrared (NIR) spectrum ranging from 650 - 1300 nm. They have the ability to be used for both image enhancement and as photosensitive markers due to their well designable scattering and absorption properties. Furthermore, their strong optical absorption permits treatment of malignant cells by photoablation processes, induced when heating them with a matched lig…
Volcanic CO_2 detection with a DFM/OPA-based lidar
2015
The DFM/OPA-based lidar BILLI was used to investigate the volcanic plume released by the hydrothermal vent of Pisciarelli, in the Campi Flegrei volcano. BILLI remotely measured CO2 concentrations in cross-sections of the nearvent plume using the differential absorption technique. To our knowledge, this is the first example of lidar-based measurement of volcanic CO2 . The spatial resolution was 1.5 m and the temporal resolution 20 s. © 2015 Optical Society of America.
Fast tracking of wind speed with a differential absorption LiDAR system: First results of an experimental campaign at Stromboli volcano
2017
Carbon dioxide ( CO 2 ) is considered a precursor gas of volcanic eruptions by volcanologists. Monitoring the anomalous release of this parameter, we can retrieve useful information for the mitigation of volcanic hazards, such as for air traffic security. From a dataset collected during the Stromboli volcano field campaign, an assessment of the wind speed, in both horizontal and vertical paths, performing a fast tracking of this parameter was retrieved. This was determined with a newly designed shot-per-shot differential absorption LiDAR system operated in the near-infrared spectral region due to the simultaneous reconstruction of CO 2 concentrations and wind speeds, using the same sample o…
Scattering and absorption imaging of a highly fractured fluid-filled seismogenetic volume in a region of slow deformation
2020
Regions of slow strain often produce swarm-like sequences, characterized by the lack of a clear mainshock-aftershock pattern. The comprehension of their underlying physical mechanisms is challenging and still debated. We used seismic recordings from the last Pollino swarm (2010–2014) and nearby to separate and map seismic scattering (from P peak-delays) and absorption (from late-time coda-wave attenuation) at different frequencies in the Pollino range and surroundings. High-scattering and high-absorption anomalies are markers of a fluid-filled fracture volume extending from SE to NW (1.5–6 Hz) across the range. With increasing frequency, these anomalies approximately cover the area where t…
The study of time-resolved absorption and luminescence in PbWO4 crystals
2000
Abstract The transient absorption and luminescence under pulsed electron beam excitation were studied for undoped and La3+ doped PbWO4 crystals. The absorption band at ∼1.0 eV is suggested to be due to self-trapped electrons and the absorption band at 3.5 eV may be due to self-trapped holes. The formation of luminescence centers via electron–hole recombination is affected by La3+ in doped crystals. The large fraction of electrons and holes undergoes thermostimulated recombination within geminate pairs and the spatial separation of geminate pairs components is important in recombination process. The intrinsic (blue) luminescence arises in this recombination. The mechanism of La3+ influence o…
Measurement of the Fluctuations in the Number of Muons in Extensive Air Showers with the Pierre Auger Observatory
2021
The successful installation, commissioning, and operation of the Pierre Auger Observatory would not have been possible without the strong commitment and effort from the technical and administrative staff in Malargue. We are very grateful to the following agencies and organizations for financial support: Argentina-Comision Nacional de Energia Atomica, Agencia Nacional de Promocion Cientifica y Tecnologica (ANPCyT), Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Gobierno de la Provincia de Mendoza, Municipalidad de Malargue, NDM Holdings and Valle Las Lenas; in gratitude for their continuing cooperation over land access; Australia-the Australian Research Council; Brazil…